GR 42x40-24 VDC Electric Motor Datasheet


Manufacturer typenumberGR 42x40-24 VDC
Manufacturer brandDunkermotoren
Commutationbrush
Short description of the motorbrushed motor

Performance data

Maximum rated output power motoraxisPrated [W]20.000
Nominal terminal voltageUnom [V]24.000
Motorconstant at standard temp. 22 oCk [Vs/rad or Nm/A]5.810e-2
Maximum torque at standstill at nominal voltageTstall [Nm]0.332
Maximum theoretical velocity motoraxis at no load (and no friction of motor and reduction) and nominal voltageω0 [rad/s]413.088
Maximum voltage allowed to prevent sparking due to brushed commutationUmax [V]24.000
Maximum output power equal to 1/4Tstallω0Pmax [W]35.378

Mechanical data

Inertia of rotorJrotor [kgm2]1.100e-5
Maximum acceleration at standstill if no load or reduction is attachedmax. accel [rad/s2]3.019e+4
Constant friction torque of motor on motoraxisTfric [Nm]0.010
Mechanical timeconstantτmech [s]1.326e-2

Electrical data

Resistance windings at standard temp. 22 oCR [Ω]4.070
Slope of the motorS [Nms/rad]8.293e-4

Thermal data

Maximum allowed temperature of windingsΘmax [oC]120.000
Maximum continuous current (thermal limit) at surround temp. 22 oC and at stillstandImax, thermal [A]1.191
Thermal resistance between rotor and ambientRth,total [K/W]12.248

Magnet data

the material of the magnetmagnetmaterialunknown
degrading of the magnetic flux density in percent per oC or KTKBr [%/K]-2.000e-1

Remarks:

  1. The frictiontorque is determined via two ways and they do not match; it is determined from the no load current and the maximum efficiency. The friction from given maximum efficiency is lower than determined from no load currrent. Used here is the no load current divided by the torque constant to be safe, so pratical values may be more favourable.
  2. The vendor has not provided magnetmaterial. The derating for the magnetstrength is not given so 'worst case' is used of -0.2%/K. The thermal resistance Rth,total is determined from given stallcurrent and derived winding resistance R. This means that the calculated temperature may be inaccurate.
  3. The winding resistance R is determined from the steepness of the motor so the value may not be accurate. This means that the calculated current and voltage may be inaccurate.
  4. Cth,total is not provided. This means that the time when thermal stability occurs can not be calculated.
  5. The vendor has not provided information about a heatsink for the given thermal information.

The quality and completeness of the supplied information has quality index: E

This quality index is determined by specAmotor.com. Here is described what the quality index is.