About specAmotorCalculation MethodConstruction Motors
This Motor
MySpec! Login
Email :
Password :
Remember Me
Forgot Password | Register

   Bookmark this datasheet Bookmark this datasheet

Serie 1524 018 SR Electric Motor Datasheet


Manufacturer typenumberSerie 1524 018 SR
Manufacturer brandFaulhaber
Commutationbrush
Short description of the motorDC-micromotor precious metal commutation

Performance data

Maximum rated output power motoraxisPrated [W]1.780
Nominal terminal voltageUnom [V]18.000
Motorconstant at standard temp. 22 oCk [Vs/rad or Nm/A]1.710e-2
Maximum torque at standstill at nominal voltageTstall [Nm]0.007
Maximum theoretical velocity motoraxis at no load (and no friction of motor and reduction) and nominal voltageω0 [rad/s]1052.632
Maximum allowed velocity motoraxisωmax [rad/s]10000.000
Maximum voltage allowed to prevent sparking due to brushed commutationUmax [V]18.000
Maximum output power equal to 1/4Tstallω0Pmax [W]1.841

Mechanical data

Inertia of rotorJrotor [kgm2]6.600e-8
Maximum acceleration at standstill if no load or reduction is attachedmax. accel [rad/s2]1.042e+5
Constant friction torque of motor on motoraxisTfric [Nm]0.000
Mechanical timeconstantτmech [s]9.931e-3

Electrical data

Resistance windings at standard temp. 22 oCR [Ω]44.000
Winding inductance measured at terminals of motorL [H]5.600e-4
Slope of the motorS [Nms/rad]6.646e-6
Electrical timeconstantτelec [s]1.273e-5

Thermal data

Maximum allowed temperature of windingsΘmax [oC]125.000
Maximum continuous current (thermal limit) at surround temp. 22 oC and at stillstandImax, thermal [A]0.217
Thermal resistance between rotor and housing motorRth1 [K/W]4.500
Thermal resistance between housing motor and ambientRth2 [K/W]31.000
Thermal contents between cupper windings and ambientCth1 [sW/K]0.533
Thermal contents between housing motor and ambientCth2 [sW/K]9.677
Thermal timeconstant between cupper windings and motorτ1 [s]2.400
Thermal timeconstant between housing motor and ambientτ2 [s]300.000

Magnet data

the material of the magnetmagnetmaterialunknown
degrading of the magnetic flux density in percent per oC or KTKBr [%/K]-3.378e-1

Remarks:

  1. The derating of the magnetstrength is estimated from a hot and a cold motorconstant and the known temperature-difference between the two situations.
  2. The vendor has not provided magnetmaterial. This means that the calculated temperature may be inaccurate.
  3. The thermal data is from the situation where no additional heatsink is attached to the motorhouse.

The quality and completeness of the supplied information has quality index: B

This quality index is determined by specAmotor.com. Here is described what the quality index is.


Advertisement