M42x30/I-211102 Electric Motor Datasheet


Manufacturer typenumberM42x30/I-211102
Manufacturer brandKAG
Commutationbrush

Performance data

Maximum rated output power motoraxisPrated [W]25.900
Nominal terminal voltageUnom [V]12.000
Motorconstant at standard temp. 22 oCk [Vs/rad or Nm/A]2.728e-2
Maximum torque at standstill at nominal voltageTstall [Nm]0.334
Maximum theoretical velocity motoraxis at no load (and no friction of motor and reduction) and nominal voltageω0 [rad/s]439.823
Maximum voltage allowed to prevent sparking due to brushed commutationUmax [V]12.000
Maximum output power equal to 1/4Tstallω0Pmax [W]38.265

Mechanical data

Inertia of rotorJrotor [kgm2]1.000e-5
Maximum acceleration at standstill if no load or reduction is attachedmax. accel [rad/s2]3.344e+4
Constant friction torque of motor on motoraxisTfric [Nm]0.014
Mechanical timeconstantτmech [s]1.264e-2

Electrical data

Resistance windings at standard temp. 22 oCR [Ω]0.941
Slope of the motorS [Nms/rad]7.912e-4

Thermal data

Maximum allowed temperature of windingsΘmax [oC]100.000
Maximum continuous current (thermal limit) at surround temp. 22 oC and at stillstandImax, thermal [A]2.832
Thermal resistance between rotor and ambientRth,total [K/W]7.910

Magnet data

the material of the magnetmagnetmaterialunknown
degrading of the magnetic flux density in percent per oC or KTKBr [%/K]-2.000e-1

Remarks:

  1. The vendor has not provided magnetmaterial. The derating for the magnetstrength is not given so 'worst case' is used of -0.2%/K. The maximum allowed temperature is not given so 'worst case' is used of 373 K. The thermal resistance Rth,total is determined from given stallcurrent and derived winding resistance R. This means that the calculated temperature may be inaccurate.
  2. The winding resistance R is determined from the steepness of the motor so the value may not be accurate. This means that the calculated current and voltage may be inaccurate.
  3. Cth,total is not provided. This means that the time when thermal stability occurs can not be calculated.
  4. The vendor has not provided information about a heatsink for the given thermal information.

The quality and completeness of the supplied information has quality index: D

This quality index is determined by specAmotor.com. Here is described what the quality index is.