10SH24 Electric Motor Datasheet


Manufacturer typenumber10SH24
Manufacturer brandADS/Transicoil
Commutationbrushless

Performance data

Nominal terminal voltageUnom [V]24.000
Maximum rated currentImax [A]36.233
Maximum rated torque at standard temp.22 oCTmax [Nm]0.545
Motorconstant at standard temp. 22 oCk [Vs/rad or Nm/A]1.504e-2
Maximum torque at standstill at nominal voltageTstall [Nm]0.551
Maximum theoretical velocity motoraxis at no load (and no friction of motor and reduction) and nominal voltageω0 [rad/s]1596.190
Maximum output power equal to 1/4Tstallω0Pmax [W]221.538

Mechanical data

Inertia of rotorJrotor [kgm2]4.940e-7
Maximum acceleration at standstill if no load or reduction is attachedmax. accel [rad/s2]1.094e+6
Constant friction torque of motor on motoraxisTfric [Nm]0.005
Velocity-dependant friction torque of motor on motoraxisCv [Nm/rad]1.960e-7
Amount of pole-pairsp2
Mechanical timeconstantτmech [s]1.420e-3

Electrical data

resistance windings measured at terminals of motor at standard temp. 22 oCR2ph [Ω]0.650
Winding inductance measured at terminals of motorL2ph [H]9.600e-5
Slope of the motorS [Nms/rad]3.478e-4
Electrical timeconstantτelec [s]1.477e-4

Thermal data

Maximum allowed temperature of windingsΘmax [oC]150.000
Maximum continuous current (thermal limit) at surround temp. 22 oC and at stillstandImax, thermal [A]4.455
Thermal resistance between rotor and ambientRth,total [K/W]6.600

Magnet data

the material of the magnetmagnetmaterialNdFeB
degrading of the magnetic flux density in percent per oC or KTKBr [%/K]-2.000e-1

Remarks:

  1. The frictiontorque is determined via two ways and they do not match; it is determined from the no load current and provided by the vendor. The friction provided by the vendor is lower than determined from no load currrent. Used here is the no load current divided by the torque constant to be safe, so pratical values may be more favourable.
  2. The derating for the magnetstrength is not given so 'worst case' is used of -0.2 %/K for the provided magnetmaterial. This means that the calculated temperature may be inaccurate.
  3. Cth,total is not provided. This means that the time when thermal stability occurs can not be calculated.
  4. The heatsink used for this motor is 4'' x 4'' x 0.125 '' Alu

The quality and completeness of the supplied information has quality index: D

This quality index is determined by specAmotor.com. Here is described what the quality index is.